SP-MBUS-40V-L


Combined coarse and fine surge protection for M-Bus networks

Application

The surge protection is designed to protect a two wire communication line of an M-Bus network against impulse overvoltage. The two stage protection protects M-Bus devices against overvoltage between the wires and between the ground and each wire. The surge protection is suitable for M-Bus slave and master devices regardless of type.

Main characteristics

  • Maximum current load 0.4A – 255 M-Bus devices.
  • Maximum M-Bus operating voltage 44V.
  • Peak surge current In(8/20μs) 10kA.
  • Serial resistance per line 2.2 Ω.
  • Plastic box with a width of just 17.5mm.

Guarantee of quality

  • In order to achieve maximum possible level of reliability and quality the devices are electrically tested and pass visual inspection during manufacturing.
Electrical properties
Operating voltage A-B 40V
Maximum operating voltage A-B 44V
Maximum operating current A,B 0.4A – 255 M-Bus slaves
Maximum operating voltage A,B to PG 90V
Peak surge current In (8 / 20 μs) 10 kA
Response time < 1ns
Maximum clamping voltage A-B at In < 74V
Maximum clamping voltage A,B to ground at In < 300V
Serial resistance per line 2.2 Ω
Connector terminals for wires of up to 2.5 mm² cross-section area
Temperature
Operating range -40°C to 80°C
Mechanical construction
Mechanical design plastic box
Mounting 35 mm DIN rail (EN 50022 top hat rail)
Dimensions: height x width x length 56.5 x 17.5 x 97.5 mm
Protection classification IP20
Weight 40g

End user

Price list for individuals and companies which do not buy converters for resale.

Pricelist

Integrator

Price list for companies which buy converters for the purpose of resale to their custommers as manufacturers or suppliers.

Pricelist (registered business partners)

The price list is available only to registered business partners.
Registration request.

Registration

Manuals

Name / File
Date
Size
Manual
Surge_Protection_MBUS-40V-L_v1_1_EN_manual.pdf
Date:
26.6. 2017
Size:
1.73 MB

Top view

back ↑

Typical application

back ↑

Connectors – protected line

Connector Type
Protected A, B Terminals for connecting the surge protected M-Bus line. Connection to the protected M-Bus device. SH-02-5.08

back ↑

Connectors – external line

Connector Type
Line A, B Terminals for connecting the M-Bus line where surges can occur. SH-02-5.08
(PG) Terminal for connecting the ground. Connect to the grounding of the electrical installation. Use the shortest possible wire with a cross-section of 2.5mm².  

back ↑

Dimensions

back ↑