EthMBus-5 SECURE
Ethernet to M-Bus communication converter
Ethernet converter with secure communication
Designed for remote secure communication with M-Bus meters using the Ethernet computer network in industry, building automation.
The converter works only as a transparent gateway for transfer of M-Bus messages using TCP or UDP Ethernet protocols. These protocols can be secured through encryption to ensure data confidentiality and integrity. Data from meters is therefore not visible and cannot be altered or tampered with during transmission over the Ethernet network. Data is available only through M-Bus protocol readout.
Main characteristics
M-Bus port
- Connection of 1 to 5 M-Bus slave devices.The most commonly used devices are heat, water, gas and electricity consumption meters.
- Surge protection with standard level of protection against overvoltage.
- Current protection against overload and short circuit on the communication line with LED status indication.
Power supply
- Wide power supply operating ranges of DC 9-39.5V and AC 9-27.5V.
- Overvoltage protection.
- LED power supply indication.
Ethernet
- TCP, UDP,TCP/AES, UDP/AES, SSH and SSL/TLS protocols and virtual COM port software.
- 10/100BASE-TX ethernet port, RJ45 connector.
Security
- SSLv3 and SSHv2 in client-server mode, configurable certificate bit length
- AES, 3DES, and RC4 encryption
- SHA-1, MD5 authentication, user access list
- Supports TLS only up to TLS v1.2
Mechanical construction
- Aluminium box with mounting on 35 mm DIN rail.
Main software characteristics
Transparent gateway mode:
- TCP/IP connection in server mode – supports multiple simultaneous connections.
- TCP/IP connection in client mode – supports multiple simultaneous connections or their fallback backups.
- UDP connection in single or multiple clients mode.

Software functions
- Converter configuration only through HTTP/HTTPS web interface or by uploading an XML file.
- TCP and UDP communication in server and client modes with encryption and authentication options.
Main differences from the EthMBus-5 SMART converter
- No SMART functions for independent readout, processing and export of M-Bus data.
- Higher power consumption.
- Support for multiple connections in TCP/IP client mode.
- HTTPS zabezpečená konfigurácia cez webové rozhranie
- Options for encrypted and secured transfer of M-Bus data.
- Doesn’t provide Telnet interface for configuration.
- Doesn’t provide logging of Ethernet activity and error states.
Guarantee of quality
- Each converter passes through several functional electrical tests during the production.
Additionally a communication test is performed after final assembly. - EMC certification in an accredited laboratory for industrial environment.
- Solid design and construction based on many years practical experience.
| Ethernet communications interface | |
|---|---|
| Communications interface | 10BASE-T, alebo 100BASE-TX (auto-sensing) |
| Communication protocols | ARP, UDP, TCP, ICMP, AutoIP, DHCP, HTTP, HTTPS, BOOTP, SMTP, SSHv2, SSLv3, TLS1.0-1.2 |
| Connector | RJ45 |
| Compatibility | Ethernet: Version 2.0/IEEE 802.3 |
| M-Bus Master communication interface | |
| Number of attachable devices | 1 to 5 SLAVE devices, idle current max. 7.5mA |
| Baud rate | 300 – 9600 bps |
| Protection | – overvoltage protection TVS 1500W |
| – electronic protection against overloads and short circuit on the communication line | |
| note: converter can withstand sustained short circuit on the communication line | |
| Galvanic separation | up to 1kV from power supply, more than 1kV from Ethernet |
| Connector | terminal block with plug-in connector for wires of up to 2.5 mm2 cross-section area |
| Power supply | |
| Recommended range of power supply voltages | |
| DC power supply | 9V to 39.5V |
| AC power supply | 9V to 27.5V |
| Maximum limits of supply voltage – permanent operation at these voltages is not recommended | |
| Minimum power supply | 8.5V DC, 8.5V AC |
| Maximum power supply | 42.5V DC, 29.5V AC |
| Protection | overvoltage protection TVS 1500W |
| Power consumption | 2.0W to 3.3W depends on load and power supply. *M-Bus line – short circuit |
| Connector | terminal block with plug-in connector for wires of up to 2.5 mm2 cross-section area |
| Status LEDs | |
| Power – green | connected power supply indication |
| Transmit – green | indication of data transmission on the M-Bus line |
| Receive – yellow | indication of data reception on the M-Bus line |
| Overload/Short – red | indication of M-Bus line overload – flashing (idle current > 8mA) |
| indication of short on the M-Bus line – turned on (resistance of the line < 500Ω) | |
| Temperature | |
| Operating range | -40°C to 60°C |
| Mechanical construction | |
| Mechanical design | aluminium box |
| Mounting | 35 mm DIN rail (EN 50022 top hat rail) |
| Dimensions: height x width x length | 33 x 57 x 87 mm – without connectors |
| 33 x 57 x 106 mm – with connectors | |
| Protection classification | IP40 |
| Weight | 136g |
EMC compatibility of the M-Bus converter has been tested according to the following standards for industrial environment.
| EMC emissions tests | ||
|---|---|---|
| Standard | Test | Level |
| EN 55011 | Power line – CONDUCTED EMISSIONS 10/150 kHz – 30 MHz | Class A |
| EN 55011 | RADIATED EMISSIONS (Electric Field) 30 MHz – 1000 MHz | Class A |
| EMC immunity tests | ||
|---|---|---|
| Standard | Test | Level |
| EN 61000-4-2 | ELECTROSTATIC DISCHARGE (ESD) – Contact discharge | ± 4 kV |
| EN 61000-4-2 | ELECTROSTATIC DISCHARGE (ESD) – Air discharge | ± 8 kV |
| EN 61000-4-3 | RADIATED RADIO-FREQUENCY ELECTROMAG. FIELD 80MHz – 1GHz | 10 V/m |
| EN 61000-4-3 | RADIATED RADIO-FREQUENCY ELECTROMAG. FIELD 1,4GHz – 2GHz | 10 V/m |
| EN 61000-4-3 | RADIATED RADIO-FREQUENCY ELECTROMAG. FIELD 2GHz – 2,7GHz | 3 V/m |
| EN 61000-4-4 | ELECTRICAL FAST TRANSIENT/BURST – Power line | ± 4 kV |
| EN 61000-4-4 | ELECTRICAL FAST TRANSIENT/BURST – M-Bus line | ± 4 kV |
| EN 61000-4-5 | SURGE IMMUNITY – Power line. Common/differential mode. | ± 1 kV / ± 1 kV |
| EN 61000-4-5 | SURGE IMMUNITY – M-Bus line. Cable shielding. | ± 4 kV |
| EN 61000-4-5 | SURGE IMMUNITY – M-Bus line. Common/differential mode.* | ± 4 kV / ± 2 kV |
| EN 61000-4-6 | CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS 0,15MHz – 80 MHZ. Power line and M-Bus line. | 10 V |
* test performed at the manufacturer’s request. The M-Bus port of the converter features an increased surge protection. This type of testing is not required when a shielded cable is used.
End user
Price list for individuals and companies which do not buy converters for resale.
Integrator
Price list for companies which buy converters for the purpose of resale to their custommers as manufacturers or suppliers.
The price list is available only to registered business partners.
Registration request.
Leaflet
Manuals
Manual of network connections for SECURE converters
Lantronix utilities
SW application from Lantronix for advanced configuration of the converters
SW application for creating a virtual COM port from Lantronix
SW application for creating a virtual COM port from Lantronix
Contents
Typical application
Typical wiring of the converter with M-Bus devices, power supply and a computer connection via Ethernet.
Connectors on the M-Bus side
| Connector | Type | |
|---|---|---|
| M-Bus | Connector for the M-Bus line. | SH-02-5.08 |
| Status LEDs | Color | |
| Transmit | indication of data transmission on the M-Bus line | green |
| Receive | indication of data reception on the M-Bus line | yellow |
| Overload/Short | indication of error, overload, collision on the M-Bus line | red |
| – indication of M-Bus line overload – flashing (idle current > 8mA) | ||
| – indication of short on the M-Bus line – turned on (resistance of the line < 500Ω) | ||
Connectors on the Power Supply and Ethernet side
| Connectors | Type | |
|---|---|---|
| Power | Connector for power supply. | SH-02-5.08 |
| Ethernet RJ45 | Connector for Ethernet cable connection. | RJ45 |
| Status LEDs | Color | |
| Power | connected power supply indication | green |
| Link | Network connection state. Turns on when a network connection is available. | green |
| Rx/Tx | Network communication activity. Flashes only during data transfer. | yellow |
Obsah
Doporučené zapojenie
Doporučené zapojenie prevodníka s M-Bus zariadeniami, napájacím zdrojom a pripojením k počítaču prostredníctvom siete Ethernet.
Konektory časť M-Bus
| Konektor | Typ | |
|---|---|---|
| M-Bus | Konektor pre pripojenie M-Bus linky. | SH-02-5,08 |
| Indikačné LED diódy | Farba | |
| Transmit | Indikácia vysielania na M-Bus linke. | zelená |
| Receive | Indikácia príjmu na M-Bus linke. | žltá |
| Overload/Short | Indikácia preťaženia, alebo skratu na M-Bus linke | červená |
| – pri preťažení LED bliká striedavo s LED Receive, I > 8mA | ||
| – pri skrate LED trvalo svieti, odpor M-Bus linky < 500Ω | ||
Konektory časť napájania a Ethernetu
| Konektory | Typ | |
|---|---|---|
| Power | Konektor pre pripojenie napájacieho napätia a uzemnenia. | SH-02-5,08 |
| Ethernet RJ45 | Konektor pre pripojenie Ethernetového kábla. | RJ45 |
| Indikačné LED diódy | Farba | |
| Power | Indikácia správneho napájacieho napätia. | zelená |
| Link | Stav sieťového pripojenia. Svieti ak je dostupné pripojenie do siete. | zelená |
| Rx/Tx | Komunikačná aktivita na sieti. Svieti len pri komunikácii, prenose dát. | žltá |