Distribution of VILTRUS products
The JSC "VILTRUS" RAY product family is comprised of data loggers / gateways / control units dedicated for smart metering, industrial metering and control, data acquisition from various meters, controllers and sensors, usage as I/O modules and so on.
Products from this family also have controller functions and can not only collect data and send it to remote users via Modbus protocol, but also can control various devices and other controllers.
The RAY family has also analog discrete inputs and outputs which can be used as I/O modules with communication capabilities.
Data Logger RAY-1
Ethernet Data Logger and Gateway with digital inputs
- Remote data readout through Ethernet
- Local data readout through RS232, RS485 or USB
- Additional converters can be connected to RS232 or RS485
- Can be used as stand-alone or as expansion module for MX-7, MX-5 and other VILTRUS data loggers
- Interfaces(1): RS232, RS485, USB, Ethernet, Discrete inputs
- Protocols: Modbus RTU, Modbus TCP/IP, IP, ICMP, UDP, TCP, DHCP, PPP, ARP, SNTP, IEC60870-5-104:2000
Data Logger RAY-2
GPRS/Ethernet Data Logger and Gateway with digital I/O
- Remote data readout through GSM/GPRS, Ethernet
- Local data readout through RS232, RS485 or USB
- Additional converters can be connected to RS232 or RS485
- Interfaces(1): RS232, RS485, USB, Ethernet, GSM/GPRS, Discrete IN/OUT
- Protocols: Modbus RTU, Modbus TCP/IP, IP, ICMP, UDP, TCP, DHCP, PPP, ARP, SNTP, IEC60870-5-104:2000
Data Logger RAY-3
Modbus Data Logger and Gateway with analog and digital I/O
- Remote data readout through GSM/GPRS, UMTS/HSPA+, Ethernet
- Local data readout through RS232, RS485 or USB
- Additional converters can be connected to RS232 or RS485
- Interfaces(1): RS232, RS485, USB, M-Bus, GSM/GPRS, UMTS/HSPA+, Ethernet, Discrete IN/OUT, Analog IN/OUT
- Protocols: Modbus RTU, Modbus TCP/IP, IP, ICMP, UDP, TCP, DHCP, PPP, ARP, SNTP, IEC60870-5-104:2000, DynDNS, FTP server, FTP client, DNS client
Data Logger RAY-6
GPRS Data Logger and Gateway with analog and digital I/O
- Remote data readout through GSM/GPRS, UMTS/HSPA+, Ethernet
- Local data readout through RS232, RS485 or USB
- Additional converters can be connected to RS232 or RS485
- Interfaces(1): RS232, RS485, M-Bus, Ethernet, USB, GSM/GPRS, UMTS/HSPA+, Discrete IN/OUT, Analog IN
- Protocols: Modbus RTU, Modbus TCP/IP, IP, ICMP, UDP, TCP, DHCP, PPP, ARP, SNTP, IEC60870-5-104:2000, DynDNS, FTP server, FTP client, DNS client
Product comparison table
Model | IN/OUT ports | Communication interfaces | System | Power supply | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MX-1 | - | - | - | - | - | 1 | - | - | - | - | 1 | - | ✓ | ✓ | 8 | ✓ | ✓ | - | - | 100-400V/ 90-250V |
MX-2 | - | - | - | - | - | - | - | - | 1 | 1 | 1 | 1 | - | - | - | - | ✓ | - | - | 50-250/ 50-250 |
MX-3 | 3 | - | 4 | - | - | 1 | 1 | - | 3 | 2 | 1 | - | ✓ | ✓ | 8 | - | ✓ | - | ✓ | 9-36/- |
MX-4 | 4 | - | 16 | 8 | - | 1 | 1 | - | 3 | 3 | 1 | - | ✓ | ✓ | 8 | - | ✓ | - | - | 9-36/- |
MX-5 | - | - | - | - | - | 2 | 2 | 2 | 4 | 3 | 1 | 1 | ✓ | ✓ | 8 | ✓ | ✓ | ✓ | - | 9-36/- |
MX-7 | 8 | - | 8 | 8 | - | 2 | 2 | 1 | 8 | 7 | 1 | 1 | ✓ | ✓ | 8 | ✓ | ✓ | ✓ | - | 9-36/- |
MX-9 | - | - | - | - | 1 | 2 | 2 | 2 | 4 | 3 | 1 | 1 | ✓ | ✓ | 8 | ✓ | ✓ | ✓ | - | 9-36/- |
RAY-1 | - | - | 32 | - | - | - | - | - | 2 | 1 | 1 | 1 | - | ✓ | 8 | - | ✓ | - | - | 9-36/- |
RAY-2 | - | - | 16 | 32 | - | - | - | - | 2 | 1 | 1 | 1 | ✓ | ✓ | 8 | - | ✓ | - | - | 9-36/- |
RAY-3 | 6 | 2 | 4 | 2 | - | 1 | - | - | 2 | 1 | 1 | 1 | ✓ | ✓ | 8 | ✓ | ✓ | - | ✓ | 9-36/- |
RAY-6 | 16 | - | 8 | 16 | - | 1 | - | - | 2 | 2 | 1 | 1 | ✓ | ✓ | 8 | - | ✓ | - | - | 9-36/- |